How to start a diesel engine that runs out of fuel?


Starting a diesel engine generator that has run out of fuel can be a challenging task, but with the right tools and techniques, it is possible to get the generator running again. Here are some steps to follow when attempting to start a diesel engine generator that has run out of fuel:


  1. Check the fuel level: The first step is ensuring the generator has run out of fuel. Sometimes, the fuel gauge may be faulty, or there may be some residual fuel in the tank that the meter did not pick up. If the generator does indeed have no energy, then you will need to add more.


  1. Add fresh fuel: If the generator has run out of power, the next step is to add new energy. It is essential to use fresh, clean fuel that is appropriate for the generator. Contaminated or stale fuel can cause problems with the generator, so it is best you avoid using energy that you have stored for a long time or that has been contaminated in some way.


  1. Bleed the fuel lines: Once you have added fresh fuel to the generator, you will need to bleed the fuel lines to remove any air that may be present. It is essential because the air in the fuel lines can prevent the generator from starting. To bleed the fuel lines, you will need to locate the fuel line bleed screws, typically located near the fuel filter or at the injectors. Using a wrench, loosen the bleed screws and allow air to escape. Once the fuel starts flowing smoothly, tighten the bleed screws again.


  1. NOTE: On bleeding, First, turn the bolt or screw on the top of the fuel filter's housing outward by a half-turn. If it is a pipe, depress and pull the fuel line with an arrow pointing outward from the fuel filter housing of a generator like the "Ecoplus" model.


  1. For the model that uses a bleeder screw, if more diesel is required to bleed the engine, you can unscrew the screw more, but do not take it out. It usually needs no more than three or four turns.


  1. Grab lots of rags because the procedure will be messy once you've loosened the bleed screw or pulled the pipe.


  1. Check the battery: If the generator has been sitting for an extended period, the battery may have become drained. If this is the case, you must charge the battery before starting the generator. To assess the battery, you will need a battery charger or a jump starter.


8. If the generator includes a starter motor, you must ensure it operates properly. Using a multimeter, you can check the voltage at the starter solenoid to test the starter motor. If the voltage is low, the starter motor will likely need to be serviced or replaced because it is failing.


9. Sometimes, you must prime the fuel system to start the generator. To start: the fuel must be manually pumped into the system. It would help if you found the primer pump and repeatedly pump it until the fuel system is primed and flowing.


  1. Attempt to start the generator: Once you have followed all the steps above, you should be ready to try and start the generator. To do this, turn the key in the ignition and engage the starter motor. If the generator starts, it will run, and you can stop the starter motor. If the generator does not start, you may need to repeat the process or troubleshoot the problem further.


You need to add fresh diesel, feed the fuel lines, inspect the battery and starter motor, and prime the fuel system if necessary to start a diesel engine generator that has run out of fuel. The generator can be restarted using the proper equipment and methods.


How to prevent diesel engines from running out of fuel in the future? 

There are a few ways to prevent diesel engines from running out of fuel in the future:

  • Use a fuel gauge or fuel level indicator: Most diesel engines have a fuel gauge showing the fuel level in the tank. Regularly checking the fuel gauge can help prevent the engine from running out of fuel.


  • Implement a fuel management system: A fuel management system can help track fuel usage and alert the operator when the fuel level is low. It can be particularly useful for fleet vehicles or frequently used equipment.


  • Follow a regular maintenance schedule: Regular maintenance can help ensure that the fuel system is functioning correctly and that there are no leaks or other issues that could cause the engine to run out of fuel.


  • Use a fuel stabilizer: Fuel stabilizers can help prevent fuel from deteriorating over time, which can help ensure that the engine has a consistent fuel supply.


  • Use a fuel filter water separator: A fuel filter water separator can help remove water and other contaminants from the fuel. It can help prevent the engine from running out of energy due to clogged fuel lines or filters


  •  If you are using an external tank, make sure the supply valve is always open and guided.


  • Replace the transparent hose (supply, return, and gauge) periodically.



By following these steps, you can help prevent diesel engines from running out of fuel in the future.